Protecting critical power with 0ms transfer time and 96.5% efficiency

Key engineering performance metrics for Riello

0 ms

Instantaneous load transfer time

96.5%

Operating efficiency in double-conversion mode

< 3%

Total harmonic distortion of current

1.0 PF

True output power factor

Environment 1 · Data centers and computing

Protecting servers and networks from any fluctuations or harmonic distortion

Data centers require superior electrical purity (THDi < 3%) and full compatibility with cooling systems and generators to ensure cloud operations never stop, even for a fraction of a second.

Environment 2 · Laboratories and medical research

Complete electrical isolation for analytical and precision microscopic equipment

Genetic testing, MRI machines, and electron microscopes cannot tolerate frequency flickers. The VFI-SS-111 architecture provides a pure sinusoidal voltage completely isolated from public grid distortions.

Environment 3 · Administrative headquarters and workspaces

Continuous readiness for workstations and corporate communication systems

Integrated protection for payment gateways, local servers, and communication systems without sacrificing quietness or energy efficiency in modern office environments.

1

Communication and conferencing systems

Uninterrupted operation for meeting rooms, display screens, and unified communication systems.

2

Servers and local payment gateways

Protecting network storage units, payment gateways, and office servers from data corruption.

3

Compact and ultra-quiet design

Silent operation and high thermal efficiency suitable for enclosed office environments without noise.

The engineering difference between Online Double Conversion and traditional systems

Riello Online Double Conversion systems

VFI-SS-111 classification (100% continuous protection)

0ms transfer time with zero flicker or interruption

Complete voltage and frequency isolation from the supply grid

Operating efficiency up to 96.5% with a 1.0 power factor

Very low harmonic distortion THDi < 3%

Traditional Line-Interactive UPS systems

Line-Interactive or Standby classification

Transfer time ranging from 4ms to 12ms

Direct load supply from the grid with partial regulation

Fluctuating efficiency with direct susceptibility to grid frequency distortions

Power factor below 0.8 - 0.9 with potential for voltage flickers

Continuous power without interruption or distortion, designed to protect the most sensitive assets in your facility.

Riello series units to cover all power ranges

From compact tower units for office and laboratory protection (Sentryum & Vision), to three-phase modular systems (Multi Sentry & Master HP) for large complexes and data centers.

TECHNICAL DATA SHEET

Technical matrix and standard specifications for the Riello UPS system

System topology

VFI-SS-111 (Online Double Conversion according to IEC EN 62040-3 standard)

Switching and transfer time

0 ms (Zero Transfer Time)

Maximum operating efficiency

96.5% in double conversion mode, and up to 99% in Smart Active mode

Input current harmonic distortion

Less than 3% (THDi < 3% @ 100% Load)

Output power factor

1.0 PF (The unit produces kW equal to kVA without power derating)

Overload capacity

110% for 60 minutes / 125% for 10 minutes / 150% for 1 minute

International certifications and standards

IEC/EN 62040-1, IEC/EN 62040-2 (EMC Class A), CE, ISO 9001, ISO 14001

Smart battery management

High-performance batteries with automatic self-testing and deep discharge protection

Ready to secure your facility's critical power with a precise engineering study?